Product Categories
Chassis Mount
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXT IEHR |
70W 150W |
11-16VDC 21-60VDC 60-132VDC |
♦12VDC ♦24VDC ♦36VDC ♦48VDC (other voltages on request) |
♦ Isolated input- output ♦ Overvoltage protection (IEXT) ♦ Short circuit protection ♦ Reverse input protection ♦ External trim pot for voltage adjustment
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXTS IEXTD |
12-60W | 9-18VDC 9.4-36VDC 18-36VDC 18-72VDC 36-72VDC |
♦ 3.3VDC ♦ 5VDC ♦ 10VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC ♦ ±3.3VDC ♦ ±5VDC ♦ ±12VDC ♦ ±15VDC |
♦ Single or dual output ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Optional leads instead of terminal block
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
APK25 APK60 |
25W 60W |
10.5-16VDC 20-30 VDC 40-60 VDC |
♦5 VDC ♦12VDC ♦15VDC ♦24VDC ♦48VDC |
♦ Fully encapsulated module ♦ Ideal for harsh environments ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Optional 110VDC input
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
9262 |
80W | 21-32VDC 40-64VDC 60-96VDC 72-110VDC |
♦13.2VDC ♦24VDC |
♦ Suitable for railway & electric forklifts ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ 130% peak capability
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW100 DCW150 DCW200 |
100W 150W 200W |
22-60VDC 65-160VDC |
♦5VDC ♦12VDC ♦24VDC ♦48VDC (5V only for DCW100) |
♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Convection cooled
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KE-F | 50-100W | 9-30VDC 16.8-30VDC 24.2-45VDC 33-60VDC 50-90VDC 77-138VDC |
♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Chassis mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
APK120 |
120W | 10.5-20VDC 18.5-40VDC 36-72 VDC 80-175 VDC |
♦12 VDC ♦13.8VDC ♦24 VDC ♦48 VDC |
♦ Fully encapsulated module ♦ Ideal for harsh environments ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ 110VDC input
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
CAB258 | 140W | 20-60VDC | 110VDC | ♦ Isolated input- output ♦ Overvoltage & short circuit protection ♦ Reverse input protection ♦ Constant current limit for charging ♦ EMI compliance to international standards ♦ Convection cooled ♦ DC OK alarm
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KEP-F | 144-200W | 16-30VDC 25-45VDC 50-90VDC 77-138VDC |
♦12VDC ♦15VDC ♦24VDC |
♦ Chassis mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection (by external fuse) ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW300 DCW500 |
300W 500W |
20-29VDC 38-60VDC 88-135VDC 12VDC option for DCW300 (250W) |
♦12VDC ♦15VDC ♦24VDC ♦48VDC ♦110VDC |
♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Convection cooled ♦ Built in output diode for N+1 ♦ DC fail alarm
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
SR500A SR500D SR500L |
500W | 99 - 150VDC | ♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC ♦96VDC ♦108VDC ♦120VDC |
♦ High reliability industrial design ♦ Isolated input to output ♦ Suitable for parallel operation # Optional temperature compensated charging # Alarms & communication options available # Optional internal digital V/I meter
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP600-1500 | 600-1500W | 21-30VDC 42-60VDC 60-85VDC 90-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦120VDC |
♦ High density/compact package. ♦ Any output voltage from 12V-120V is possible. ♦ Suitable for battery charging applications. ♦ N+1 redundancy option. ♦ Alarm option, optocoupler or relay. ♦ Full electronic protection & field proven design topology. ♦ Quality components, high MTBF >100,000 hrs. ♦ Thermal shutdown. ♦ Meets international safety and EMC standards.
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP319F | 750W | 42-60VDC 60-85VDC 90-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦125VDC |
♦ Input voltage options from 48 - 140VDC ♦ Output voltage options 12 - 125VDC ♦ Constant current overload protection ♦ Input - Output isolation ♦ Suitable for a wide range of Industrial and Telecom applications ♦ Battery charging option ♦ Field proven reliability design ♦ N+1 Redundancy option ♦ Alarm option ♦ Customer specified input and output voltage options
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP765F | 750-1500W | 21-29VDC 42-60VDC 60-85VDC 90-140VDC |
♦24VDC ♦48VDC ♦72VDC ♦110VDC |
♦ Input voltage options from 24 - 140VDC ♦ Output voltage options 12 - 125VDC ♦ Power level input voltage dependent up to 1500 watts ♦ Constant current overload protection ♦ Input - Output isolation ♦ Suitable for a wide range of Industrial and Telecom applications ♦ Battery charging option ♦ Field proven reliability design ♦ N+1 Redundancy option ♦ Alarm option ♦ Customer specified input and output voltage options
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP1K | 1000W | 21-30VDC 42-60VDC 95-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦120VDC |
♦ 24- 160vdc Input options ♦ 1000 watts output power ♦ Over voltage protection ♦ Overload and short circuit protection ♦ MTBF > 130,000hrs ♦ Any output from 24vdc ~ 130vdc possible ♦ N+1 Redundancy Applications – option ♦ Output DC Fail alarm -Option ♦ Battery Charging applications - Option
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
VADS300 VADS500 VADS600 VADS1000 VADS1500 |
240-300W 430-500W 516-600W 960-1120W 1440-1500W |
20-36VDC 36-76VDC 85-185VDC 200-400VDC |
♦12VDC ♦15VDC ♦24VDC ♦28VDC ♦48VDC |
♦ Wide DC input voltage range ♦ Reverse polarity protection ♦ Output voltage trim option ♦ Floating output ♦ Regulated output ♦ Over current and over voltage correction ♦ Fully isolated to 3000VDC ♦ N+1 redundancy - Option “D” ♦ Relay alarm - Option “R” ♦ MTBF>200,000 hours
|
|
|
| ||||||