Product Categories
DC - DC Converters: Industrial
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXTS IEXTD |
12-60W | 9-18VDC 9.4-36VDC 18-36VDC 18-72VDC 36-72VDC |
♦ 3.3VDC ♦ 5VDC ♦ 10VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC ♦ ±3.3VDC ♦ ±5VDC ♦ ±12VDC ♦ ±15VDC |
♦ Single or dual output ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Optional leads instead of terminal block |
|
|
| ||||||
Request a Quote
![]() Chassis Mount (16) |
![]() PCB Mount - incl chassis mount options (7) |
![]() Power Modules (for OEM) (2) |
Euro Cassette - incl chassis mount options (5) |
Chassis Mount |
||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXT IEHR |
70W 150W |
11-16VDC 21-60VDC 60-132VDC |
♦12VDC ♦24VDC ♦36VDC ♦48VDC (other voltages on request) |
♦ Isolated input- output ♦ Overvoltage protection (IEXT) ♦ Short circuit protection ♦ Reverse input protection ♦ External trim pot for voltage adjustment
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
IEXTS IEXTD |
12-60W | 9-18VDC 9.4-36VDC 18-36VDC 18-72VDC 36-72VDC |
♦ 3.3VDC ♦ 5VDC ♦ 10VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC ♦ ±3.3VDC ♦ ±5VDC ♦ ±12VDC ♦ ±15VDC |
♦ Single or dual output ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Optional leads instead of terminal block
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
APK25 APK60 |
25W 60W |
10.5-16VDC 20-30 VDC 40-60 VDC |
♦5 VDC ♦12VDC ♦15VDC ♦24VDC ♦48VDC |
♦ Fully encapsulated module ♦ Ideal for harsh environments ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Optional 110VDC input
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
9262 |
80W | 21-32VDC 40-64VDC 60-96VDC 72-110VDC |
♦13.2VDC ♦24VDC |
♦ Suitable for railway & electric forklifts ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ 130% peak capability
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW100 DCW150 DCW200 |
100W 150W 200W |
22-60VDC 65-160VDC |
♦5VDC ♦12VDC ♦24VDC ♦48VDC (5V only for DCW100) |
♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Convection cooled
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KE-F | 50-100W | 9-30VDC 16.8-30VDC 24.2-45VDC 33-60VDC 50-90VDC 77-138VDC |
♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Chassis mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
APK120 |
120W | 10.5-20VDC 18.5-40VDC 36-72 VDC 80-175 VDC |
♦12 VDC ♦13.8VDC ♦24 VDC ♦48 VDC |
♦ Fully encapsulated module ♦ Ideal for harsh environments ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ 110VDC input
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
CAB258 | 140W | 20-60VDC | 110VDC | ♦ Isolated input- output ♦ Overvoltage & short circuit protection ♦ Reverse input protection ♦ Constant current limit for charging ♦ EMI compliance to international standards ♦ Convection cooled ♦ DC OK alarm
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KEP-F | 144-200W | 16-30VDC 25-45VDC 50-90VDC 77-138VDC |
♦12VDC ♦15VDC ♦24VDC |
♦ Chassis mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection (by external fuse) ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
DCW300 DCW500 |
300W 500W |
20-29VDC 38-60VDC 88-135VDC 12VDC option for DCW300 (250W) |
♦12VDC ♦15VDC ♦24VDC ♦48VDC ♦110VDC |
♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ Convection cooled ♦ Built in output diode for N+1 ♦ DC fail alarm
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
SR500A SR500D SR500L |
500W | 99 - 150VDC | ♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC ♦96VDC ♦108VDC ♦120VDC |
♦ High reliability industrial design ♦ Isolated input to output ♦ Suitable for parallel operation # Optional temperature compensated charging # Alarms & communication options available # Optional internal digital V/I meter
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP600-1500 | 600-1500W | 21-30VDC 42-60VDC 60-85VDC 90-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦120VDC |
♦ High density/compact package. ♦ Any output voltage from 12V-120V is possible. ♦ Suitable for battery charging applications. ♦ N+1 redundancy option. ♦ Alarm option, optocoupler or relay. ♦ Full electronic protection & field proven design topology. ♦ Quality components, high MTBF >100,000 hrs. ♦ Thermal shutdown. ♦ Meets international safety and EMC standards.
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP319F | 750W | 42-60VDC 60-85VDC 90-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦125VDC |
♦ Input voltage options from 48 - 140VDC ♦ Output voltage options 12 - 125VDC ♦ Constant current overload protection ♦ Input - Output isolation ♦ Suitable for a wide range of Industrial and Telecom applications ♦ Battery charging option ♦ Field proven reliability design ♦ N+1 Redundancy option ♦ Alarm option ♦ Customer specified input and output voltage options
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP765F | 750-1500W | 21-29VDC 42-60VDC 60-85VDC 90-140VDC |
♦24VDC ♦48VDC ♦72VDC ♦110VDC |
♦ Input voltage options from 24 - 140VDC ♦ Output voltage options 12 - 125VDC ♦ Power level input voltage dependent up to 1500 watts ♦ Constant current overload protection ♦ Input - Output isolation ♦ Suitable for a wide range of Industrial and Telecom applications ♦ Battery charging option ♦ Field proven reliability design ♦ N+1 Redundancy option ♦ Alarm option ♦ Customer specified input and output voltage options
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
BAP1K | 1000W | 21-30VDC 42-60VDC 95-140VDC |
♦12VDC ♦24VDC ♦48VDC ♦120VDC |
♦ 24- 160vdc Input options ♦ 1000 watts output power ♦ Over voltage protection ♦ Overload and short circuit protection ♦ MTBF > 130,000hrs ♦ Any output from 24vdc ~ 130vdc possible ♦ N+1 Redundancy Applications – option ♦ Output DC Fail alarm -Option ♦ Battery Charging applications - Option
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
VADS300 VADS500 VADS600 VADS1000 VADS1500 |
240-300W 430-500W 516-600W 960-1120W 1440-1500W |
20-36VDC 36-76VDC 85-185VDC 200-400VDC |
♦12VDC ♦15VDC ♦24VDC ♦28VDC ♦48VDC |
♦ Wide DC input voltage range ♦ Reverse polarity protection ♦ Output voltage trim option ♦ Floating output ♦ Regulated output ♦ Over current and over voltage correction ♦ Fully isolated to 3000VDC ♦ N+1 redundancy - Option “D” ♦ Relay alarm - Option “R” ♦ MTBF>200,000 hours
|
|
|
| ||||||
PCB Mount |
||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
PP | 1.5-25W (single output) 1.5-10W (dual output) |
4.5-7.2VDC 9-18VDC 18-36VDC 36-72VDC |
♦ 5VDC ♦ 12VDC ♦ 24VDC ♦ 48VDC ♦ ±12VDC ♦ ±15VDC |
♦ PCB mount ♦ Input to output isolation ♦ constant current limiting on overload ♦ External voltage trim for 15 & 25W ♦ Voltage trim for 15 and 25 watt models ♦ Remote control for 15 and 25 watt models
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
FDC15 | 15W | 9-36VDC 18-75VDC |
♦ 5V ♦ 12V ♦ 15V ♦ ±5V ♦ ±12V ♦ ±15V |
♦ PCB mount ♦ Input to output isolation ♦ Short circuit,overload,overvoltage protection ♦ 4:1 wide input range ♦ External voltage trim
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
FEC30(W) | 30W | 9-36VDC 18-75VDC |
♦ 1.5V ♦ 1.8V ♦ 2.5V ♦ 3.3V ♦ 5V ♦ 12V ♦ 15V ♦ ±12V ♦ ±15V |
♦ PCB mount ♦ Input to output isolation ♦ 2:1 standard input range ♦ 4:1 wide input range option (W) ♦ Single and dual outputs ♦ Industry standard 2 x 1.6in package ♦ High efficiency up to 90% ♦ Regulated output and short circuit protection ♦ Remote ON/OFF ♦ High operating temperature +85°C
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
FEC40W | 40W | 9-36VDC 18-75VDC |
♦ 3.3V ♦ 5V ♦ 12V ♦ 15V ♦ ±12V ♦ ±15V |
♦ PCB mount ♦ Input to output isolation ♦ 4:1 wide input range option ♦ Single and dual outputs ♦ Industry standard 2 x 2in package ♦ High efficiency up to 90% ♦ Regulated output and short circuit protection ♦ Remote ON/OFF ♦ High operating temperature +85°C
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/Js AVP/Jsp |
24-53W | 8-36VDC 9-40VDC 15-36VDC 32-74VDC 66-154VDC |
♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC |
♦ PCB (/Jsp) or chassis mount (/Js) ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection (by external fuse) ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/J AVP/K |
24-42W (/J) 38-75W (/K) |
8-36VDC 9-40VDC 15-36VDC 32-74VDC 66-154VDC |
♦ 3.4VDC ♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC |
♦ PCB mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection (by external fuse) ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/Ks, AVP/Ksl, AVP/Ksp | 33-78W | 8-36VDC 9-40VDC 15-36VDC 32-74VDC 66-154VDC |
♦ 3.4VDC ♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC ♦ 30VDC |
♦ PCB (/Ksp) or chassis mount (/Ks, /Ksl) ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection (by external fuse) ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
Power Modules |
||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
HAE75W |
75W | 9-36VDC 18-75VDC |
♦3.3VDC ♦5VDC ♦12VDC ♦15VDC ♦24VDC ♦28VDC ♦48VDC |
♦ 4:1 wide Input range ♦ Industry Standard Half-Brick package ♦ Input to output isolation 2250VDC ♦ Short circuit,overload,overvoltage protection ♦ External output voltage trim # Optional terminal block # Optional standalone with base plate, code KAE…
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
HAE100 |
100W | 18-36VDC 36-75VDC |
♦5VDC ♦12VDC ♦15VDC ♦24VDC ♦28VDC ♦48VDC |
♦ Industry Standard Half-Brick package ♦ Input to output isolation 2250VDC ♦ Short circuit,overload,overvoltage protection ♦ External output voltage trim # Optional terminal block # Terminal block option -T
|
|
|
| ||||||
Euro Cassette |
||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KE | 51-100W | 9-30VDC 16.8-30VDC 24.2-45VDC 33-60VDC 50-90VDC 77-138VDC |
♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Euro cassette - 19" rack mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KE-S | 51-100W | 9-30VDC 16.8-30VDC 24.2-45VDC 33-60VDC 50-90VDC 77-138VDC |
♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Euro cassette - 19" rack mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B (QP)* ♦ Reverse polarity protection ♦ Zero load operation and short circuit protected ♦ Parallel and series connection ♦ Overtemperature shutdown ♦ No overshoot of output voltage at switching on ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
QoneLEC | 60-160W | 8-15VDC 16-30VDC 10-30VDC 24-45VDC 33-60VDC 48-90VDC |
♦ 3.4VDC ♦ 5.1VDC ♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Euro cassette (LEC) with chassis mount options (LEC-C, LEC-CS) ♦ High power density ♦ Fully integrated heatsink (or mounting surface) ♦ Coated & partially encapsulated for better vibration resistance ♦ Overtemperature and overvoltage shutdown ♦ Short circuit protection ♦ Remote on/off ♦ Yellow LED indicates operating mode ♦ Reverse polarity protection
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
AVP/KEP | 144-200W | 16-30VDC 25-45VDC 50-90VDC 77-138VDC |
♦ 12VDC ♦ 15VDC ♦ 24VDC |
♦ Euro cassette - 19" rack mount ♦ Conducted immunity according to EN 61000-4-6:2007 ♦ Input filtering according to EN 55022:2006, class B ♦ Reverse polarity protection by internal diode ♦ Zero load operation and short circuit protected ♦ Overtemperature shutdown ♦ Remote off (EN) with TTL – L-signal ♦ Overvoltage protection in the output circuit ♦ Reverse polairty protection by internal diode
|
|
|
| ||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
C200 to CW6600 |
40 to 30,000W |
10V to 800VDC |
5V to 400VDC |
Go to Schaefer DC/DC converters
|
|




















.jpg)






























