| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
SR100C |
100W | Standard 180-264VAC Optional 88-132VAC Optional 100-140VDC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Low voltage disconnect, battery overload protection ♦ 2 x alarm relays with c/o contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional automatic battery condition testing # Can be used for N+1 redundancy ♦ Mounting: Std. = feet, Opt.=rack
|
|
|
| ||||||
![]() |
SR100i |
100W | Standard 180-264VAC Optional 88-132VAC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Communications port - ethernet (ASCII, SNMP) or serial (RS485, RS232) ♦ Automatic battery condition testing ♦ Low voltage disconnect, battery overload protection ♦ 2 alarm relays with changeover contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional Modbus protocol converter # Optional wall mount enclosure # Optional rack mounting # Can be used for N+1 redundancy
|
|
|
| ||||||
![]() |
SR250C |
250W | Standard 180-264VAC Optional 88-132VAC Optional 100-140VDC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Low voltage disconnect, battery overload protection ♦ 2 x alarm relays with c/o contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional wall mount enclosure # Optional rack mounting # Optional automatic battery condition testing # Can be used for N+1 redundancy
|
|
|
| ||||||
![]() |
SR250i |
250W | Standard 180-264VAC Optional 88-132VAC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Communications port - ethernet (ASCII, SNMP) or serial (RS485, RS232) ♦ Automatic battery condition testing ♦ Low voltage disconnect, battery overload protection ♦ 2 alarm relays with changeover contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional Modbus protocol converter # Optional wall mount enclosure # Optional rack mounting # Can be used for N+1 redundancy
|
|
|
| ||||||
![]() |
SR250V |
250W | Standard 180-264VAC Optional 88-132VAC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Dual battery outputs ♦ Communication enabled - choice of ethernet (ASCII, SNMP) or serial (RS485, RS232) ♦ Automatic battery condition testing ♦ Low voltage disconnect, battery overload protection ♦ 2 alarm relays with c/o contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional wall mount enclosure # Optional rack mounting # Optional Modbus protocol converter # Can be used for N+1 redundancy
|
|
|
| ||||||
![]() |
SR500C |
500W | Standard 180-264VAC Optional 88-132VAC Optional 100-140VDC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Low voltage disconnect, battery overload protection ♦ 2 x alarm relays with c/o contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional wall mount enclosure # Optional rack mounting # Optional automatic battery condition testing # Can be used for N+1 redundancy # Optional internal digital V/I meter
|
|
|
| ||||||
![]() |
SR500i | 500W | Standard 180-264VAC Optional 88-132VAC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Communications port - ethernet (ASCII, SNMP) or serial (RS485, RS232) ♦ Automatic battery condition testing ♦ Low voltage disconnect, battery overload protection ♦ 2 alarm relays with changeover contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional Modbus protocol converter # Optional wall mount enclosure # Optional rack mounting # Can be used for N+1 redundancy
|
|
|
| ||||||
![]() |
SR750C |
750W | Standard 180-264VAC Optional 88-132VAC Optional 100-140VDC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Low voltage disconnect, battery overload protection ♦ 2 x alarm relays with c/o contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional wall mount enclosure # Optional rack mounting # Optional automatic battery condition testing # Can be used for N+1 redundancy # Optional internal digital V/I meter
|
|
|
| ||||||
![]() |
SR750i | 750W | Standard 180-264VAC Optional 88-132VAC |
♦12VDC ♦24VDC ♦30VDC ♦36VDC ♦48VDC |
♦ Communications port - ethernet (ASCII, SNMP) or serial (RS485, RS232) ♦ Automatic battery condition testing ♦ Low voltage disconnect, battery overload protection ♦ 2 alarm relays with changeover contacts ♦ High reliability industrial design ♦ Automatic temperature compensated charging ♦ Automatic battery presence checking # Optional Modbus protocol converter # Optional wall mount enclosure # Optional rack mounting # Can be used for N+1 redundancy
|
|
|
| ||||||
Security Cabinets |
||||||
| Product | Series | Power | Input (V) | Output (V) | Features | |
![]() |
SE |
75W 150W |
90-264VAC |
♦12VDC ♦24VDC |
♦ Individual fused outputs ♦ 2 alarm relay outputs ♦ Reverse polarity connection protection ♦ Battery low voltage disconnect ♦ Switch mode design
|
|
|
| ||||||
![]() |
SL |
35W 40W 70W 138W |
218-240VAC |
♦12VDC ♦24VDC |
♦ Linear design for low EMI ♦ Individual fused outputs ♦ Alarm relay outputs ♦ Reverse polarity connection protection ♦ Battery low voltage disconnect
|
|
|
| ||||||